Search results for "harmonic analysis"

showing 10 items of 75 documents

Maximal function estimates and self-improvement results for Poincaré inequalities

2018

Our main result is an estimate for a sharp maximal function, which implies a Keith–Zhong type self-improvement property of Poincaré inequalities related to differentiable structures on metric measure spaces. As an application, we give structure independent representation for Sobolev norms and universality results for Sobolev spaces. peerReviewed

Discrete mathematicsPure mathematicsGeneral Mathematics010102 general mathematicsAlgebraic geometryharmoninen analyysi01 natural sciencesUniversality (dynamical systems)Sobolev inequalitySobolev spacesymbols.namesakeNumber theoryinequalities0103 physical sciencesPoincaré conjecturesymbolsharmonic analysisMaximal function010307 mathematical physicsDifferentiable function0101 mathematicsfunktionaalianalyysiepäyhtälötMathematics
researchProduct

Metrological performances of voltage and current instrument transformers in harmonics measurements

2018

In the new electrical system scenario, the increasing presence of non-linear loads and renewable energy sources makes the measurement of harmonics an essential task. The accuracy of harmonic measurement firstly depends on the used instrument transformers for voltage and current sensing. Since the behavior of instrument transformers in non-sinusoidal conditions is not always well defined, this paper presents an experimental study on the metrological performances of current and voltage instrument transformers (CTs and VTs) in the presence of harmonics. Proper tests procedures are defined and measurement setups are developed for both CTs and VTs calibration. The analysis is carried out by usin…

instrument transformers020209 energy02 engineering and technologyInstrument TransformerHarmonic analysispower system meaurementsPhase AngleDistortionharmonics0202 electrical engineering electronic engineering information engineeringCalibrationElectronic engineeringMedicineSafety Risk Reliability and QualityInstrumentationbusiness.industry020208 electrical & electronic engineeringHarmonicPower System MeasurementcalibrationCurrent transformerMetrologyHarmonicsHarmonicbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage
researchProduct

Optimizing and comparing gap-filling techniques using simulated NDVI time series from remotely sensed global data

2019

Abstract NDVI (Normalized Difference Vegetation Index) time series usually suffer from remaining cloud presence, even after data pre-processing. To address this issue, numerous gap-filling (or reconstruction) techniques have been developed in the literature, although their comparison has mainly been local to regional, with only two global studies to date, and has led to sometimes contradictory results. This study builds on these different comparisons, by testing different parameterizations for five NDVI temporal profile reconstruction techniques, namely HANTS (Harmonic Analysis of Time Series), IDR (iterative Interpolation for Data Reconstruction), Savitzky-Golay, Asymmetric Gaussian and Do…

Global and Planetary Change010504 meteorology & atmospheric sciencesSeries (mathematics)business.industryComputer scienceGaussian0211 other engineering and technologiesCloud computing02 engineering and technologyManagement Monitoring Policy and Law01 natural sciencesNormalized Difference Vegetation IndexHarmonic analysissymbols.namesakeBenchmark (surveying)Range (statistics)symbolsComputers in Earth Sciencesbusiness021101 geological & geomatics engineering0105 earth and related environmental sciencesEarth-Surface ProcessesRemote sensingInterpolationInternational Journal of Applied Earth Observation and Geoinformation
researchProduct

Current transformers effects on the measurement of harmonic active power in LV and MV networks

2011

The harmonic active power is used to determine the location of polluting loads, the direction of harmonic power flow and to estimate how consequential a certain current harmonic source is. The highest uncertainties, when measuring harmonic active power, are introduced by the current and voltage transducers. This paper presents experimental results which show the impact of current transformers (CTs) on the accuracy of the harmonic power measurements. An expression for the evaluation of the power error in distorted conditions was developed which can be easily utilized in the case of linear current transducers. It is shown how CTs cannot be considered linear transducers and how the higher the …

instrument transformersEngineeringVoltage and current harmonicsSwitched-mode power supplyAcousticsActive powerTransducersEnergy Engineering and Power TechnologyLinear currentsPower factorHarmonic powerLinear transducersPower errorsPower transformersVoltage transducersHarmonic analysisHarmonic analysisMaximum valuesCurrent transformerElectrical and Electronic EngineeringPower measurementPhase anglesAbsolute valuesHarmonic power flowTotal harmonic distortionbusiness.industryElectric power distributionCurrent harmonicsElectrical engineeringAC powerCurrent transformerMV networksHarmonicsAccuracy classElectric instrument transformersHarmonicPower system harmonicsCurrent transformers (CTs) instrument transformerspower measurement power system harmonics.businessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Characterization and Error Compensation of a Rogowski Coil in the Presence of Harmonics

2011

This paper reports the results of an experimental study dealing with a commercial Rogowski coil current transducer (RCCT) in the presence of harmonic distortion. The RCCT was observed under two conditions: 1) sinusoidal excitation with frequencies from 50 to 750 Hz and 2) nonsinusoidal excitation using fundamental frequency and one harmonic, with adjustable amplitude and phase shift. The experimental results show only a weak dependence of the harmonic current ratio error and phase displacement on the amplitude and phase shift of the excitation harmonic. The phase displacement is also independent of the conductor position within the Rogowski coil window. An error compensation method, based o…

PhysicsTotal harmonic distortionFrequency responsebusiness.industryAcousticsElectrical engineeringFundamental frequencycurrent transducerRogowski coilCurrent measurement current transducer frequency response harmonic distortion power system harmonics Rogowski coil.harmonic distortionHarmonic analysisAmplitudeHarmonicsHarmonicpower system harmonicElectrical and Electronic EngineeringbusinessInstrumentationSettore ING-INF/07 - Misure Elettriche E ElettronicheRogowski coil
researchProduct

SEA LEVEL VARIATIONS AT THE LATVIAN COASTAL HYDROLOGIC STATIONS

2016

The objective of this paper is to analyse water level variations of the Baltic Sea on the Latvian coast. This is important because the Baltic Sea exhibits a number of remarkable phenomena. One of them is the sea level variations due to winds, complicated by the shape of the gulfs and islands. Under this influence the range of the sea level variations can reach 3 m on the coasts of gulfs. However, the tidal variations of the Baltic Sea range in the order of centimetres only. In the frame of this study, using hourly time series of the sea level records from 7 Latvian coastal hydrologic stations and employing spectral analysis, it has become feasible to identify diurnal and semi-diurnal tide e…

0106 biological sciencesQB275-343010504 meteorology & atmospheric sciencesRange (biology)010604 marine biology & hydrobiologyLatviansea leveltide gauge01 natural scienceslanguage.human_languageWater levelOceanographyGeographyBaltic seaharmonic analysis of tidelanguageGeneral Earth and Planetary SciencesSpectral analysisTide gaugeGeodesySea level0105 earth and related environmental sciencesGeodesy and cartography
researchProduct

Improvement of Hall Effect Current Transducer Metrological Performances in the Presence of Harmonic Distortion

2010

The performance of Hall effect current transducers (HECTs), under distorted waveform conditions, is usually characterized by means of a frequency response test. In this paper, it was investigated if frequency response is able to correctly evaluate the ratio and the phase errors under distorted conditions. Two HECTs, with the accuracy class level of 1% and 0.5%, respectively, were experimentally characterized under two conditions: 1) sinusoidal excitation with frequencies ranging from 50 to 750 Hz, which is the well-known frequency response test, and 2) nonsinusoidal excitation using fundamental frequency and one harmonic with adjusted amplitude and phase shift. It was found that ratio and p…

Frequency responseElectric current measurementCurrent measurement current transducer frequency response hall effect devices harmonic distortion power system harmonics.AcousticsTransducersPhase (waves)GyratorsNon-sinusoidal excitationHarmonic distortionAccuracy levelFundamental frequenciesHarmonic analysisPhase errorElectric currentsError compensationFrequency responseFrequency response testsWaveformSinusoidal excitationsPhase shiftElectrical and Electronic EngineeringInstrumentationPhysicsTotal harmonic distortionElectric power distributionHall effectCurrent measurementsMetrological performanceCurrent transducerFundamental frequencyLight measurementAmplitudeAccuracy classHarmonicsMagnetic field effectsHarmonicHarmonic amplitudeSettore ING-INF/07 - Misure Elettriche E ElettronicheDistorted waveformsHarmonic componentsHall effect devicesIEEE Transactions on Instrumentation and Measurement
researchProduct

Characterization of clamp-on current transformers under nonsinusoidal conditions

2009

This paper reports the performance of clamp-on current transformers under nonsinusoidal conditions. A set of experimental measurements helped to determine the ratio and the phase errors under two conditions: 1) sinusoidal excitation with frequencies from 45 to 1000 Hz and 2) nonsinusoidal excitation using the fundamental frequency and one harmonic, with adjusted phase shift. It was found that ratio and phase errors are affected by the phase angle between the harmonic and the fundamental and the harmonic amplitude. The effects of conductor location in the current transformer's window and of the air-gap width were also investigated. It was concluded that harmonic phase and ratio errors measur…

Frequency responseMaterials scienceElectric current measurementTransductorAcousticsErrorsTransducersPhase (waves)Energy Engineering and Power TechnologyClamp-on current transformers current transformers (CTs) frequency response power system harmonics transducers.Power transformersDistributed power generationElectric power systemsHarmonic analysisElectric power transmission networksClamp-on current transformersCurrent transformersFrequency responsePower electronicsFrequency measurementElectronic engineeringElectrical and Electronic EngineeringElectrical conductorTomographyComputed tomographyElectric power distributionElectric transformersCircuit faultsFault currentsFundamental frequencyComputerized tomographyFourier seriesCurrent measurementCurrent transformerDiagnostic radiographyElectric instrument transformersElectric frequency measurementPower system harmonicsMedical imagingCurrent transformers (CTs)Air gap (plumbing)Power transmissionElectric network analysisExcitation
researchProduct

Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis

2017

This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard…

Engineeringarc fault detection020209 energyseries arcsArc-fault circuit interrupter02 engineering and technologyUL 1699Fault detection and isolationlaw.inventionHarmonic analysisElectric arcarc fault circuit interrupter (AFCI)Arc dischargeslawArc discharges arc fault circuit interrupter (AFCI) arc fault detection electrical safety fault diagnosis home protection interrupters power system harmonics power system measurements series arcs UL 1699Fault current limiterhome protection0202 electrical engineering electronic engineering information engineeringElectronic engineeringElectrical and Electronic EngineeringInstrumentationpower system harmonicsinterruptersbusiness.industry020208 electrical & electronic engineeringfault diagnosispower system measurementsFault indicatorElectrical networkHarmonicelectrical safetybusinessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Enhanced Modelling for Extended Performance Analysis of Interior Permanent Magnet Synchronous Machine Drive fed with Cascaded H-Bridges Multilevel In…

2021

This paper presents a comparative simulation analysis of an Interior Permanent Magnet Synchronous Machine (IPMSM) performance once fed by a traditional three-phase two-level inverter and then using a three-phase five-level Cascaded H-Bridges Multilevel Inverter (CHBMI). For this purpose, an enhanced mathematical model of the IPMSM, that take into account simultaneously saturation, cross-coupling, spatial harmonics and iron loss effects, has been employed. Furthermore, two different PWM modulation strategies have been considered. The study was conducted for several working conditions, evaluating the impact of CHBMI adoption on the IPMSM performance in terms of improved efficiency and torque …

Cascaded H-bridges Multilevel Inverter (CHBMI)Computer scienceSettore ING-IND/32 - Convertitori Macchine E Azionamenti Elettricitorque rippleHarmonic analysisControl theoryModulationefficiencyMultilevel inverterInterior Permanent Magnet Synchronous Machine (IPMSM)InverterTorque rippleReduction (mathematics)Permanent magnet synchronous machinePulse-width modulationIEEE
researchProduct